• Tap doan Rosenberg
  • Box fans
  • Dong Co EC
  • Slide 01

DVW

DVW... / DHW... - Roof fans vertical or horizontal outlet
 
·    easy to install
·    weatherproof housing
·    Motor protection by thermal contacts
_____________________________________________________________________________________________________

 Features and Constructions:

 The  Rosenberg  roof  fans  are  used  for  ventilation  of  department  stores,  supermarkets,  factories,  swimming  pools, kitchens,  dining  halls,  warehouses,  garages,  farms  and  stables.  The  fans are suitable  for  mounting on a flat or any shaped roof.

 Application areas:
 Garage  / Offices  /  Bars /  Greenhouses  / Skyscrapers  / Hotels / Industrial buildings /  Basement rooms /  Playschool / Cinemas  /  Parking facilities  / Warehouses  /  Nursing homes  /  Schools  / Sports halls /  Supermarkets / Workshops /  Residential houses / Fitness centers / Inflatables

  We distinguish between...
  ... Type DH with horizontal outlet         = for less polluted air
  ... Type DV with vertical outlet                    = for heavily contaminated air

 Classification of the fan series:
 NRVU    = Non Residential Ventilation Units
  UVU    = Unidirectional Ventilation Units

 Reference to Directives:
  Declaration of incorporation and operating instruction are according to Machinery Directive 2006/42/EC, CE dentification in accordance  to  EMC-Directive  2014/30/EU, Low Voltage Directive 2014/35/EU and the Ecodesign-Directive 2009/125/EC.
_____________________________________________________________________________________________________

 Casing:

 Vertical type DVW:
 Casing made of seawater-resistant aluminium  

 Horizontal type DHW:
 Up to size 500:  Casing made of seawater-resistant aluminium,
 From size 560:  Casing made of galvanized sheet steel.

 Base frame:
 up to size 500    : Base  frame  with  bolts  for  tightening of inlet accessories and rectangular inlet cone made of galvanized steel.

 from size 560:     Base  frame  with  bolts  for  tightening  of inlet accessories and rectangular inlet cone made of galvanized steel, additionally plastic coated.

  Coating:
  Standard Coating RAL 7030 / RAL 7035 or other coating possible on request against extra charge.

  Bird Protection Grill:
  A coated grill RAL 9005 (black), ensures an optimal protection. Inlet grill possible on request.
_____________________________________________________________________________________________________

 Impellers:

 Efficiency  optimized  backward  curved  impellers  made  of  aluminium.  Impellers are mounted directly to the rotor of the external  roto r motor  and are balanced dynamically at two levels together with the rotor according to quality level G 6.3 to DIN 1940.
_____________________________________________________________________________________________________

 Motors:

  Used  are external rotor motors with IP 44/54 according to DIN EN 60034-5 with moisture protection, ball bearing mounted and with thermal contacts as motor protection.

 Motor protection class IP 54.

  The  drive has  due to an external rotor motor a space saving, compact and attractive design. The motor is fitted within the  impeller,  which  enables  the  best  possible  cooling.  For this  reason a 100% variable speed control can be guaranteed.
  V-belts, additional tension bars and motor mounting devices are not necessary. Only well-dimensioned ball-bearings, fitted on both sides with long life time grease are used. Both ball-bearing seats are ground to superfinish in one work process  to eliminate any vibrations. External rotor motors have extremely low starting currents. The windings comply to isolation class  F. In addition the windings have a standard moisture impregnation.

  UL-Permit:
  For 60Hz Types (possible on request)
_____________________________________________________________________________________________________

 Electrical connection:

  The  motors  are  equipped with a built-on terminal box in protection class IP 54 with easy access for electrical connection after removal of the rain cover. Upon request the isolator switch (against extra charge) can be mounted on the casing of the fan.
_____________________________________________________________________________________________________

 Air volume control:
 For more information see accessories!

  Reference:
  Please note the directives 1253/2014/EU (Lot 6) applying from 01.01.2016 for the ventilation units (ventilation fans).
  Keyword: „Multi-stage drive" (at least 3 fixed speeds, as well as speed 0  („off"). Suitable control and regulation devices are available as accessories.

 5-speed control unit:    
 230V   à RTE
 400V   à   RTD

 Infinitely variable control unit:
 230V   à   ED / REE
 400V   à   RED
 400V   à   via Frequency converter (available on request)
                   WARNING : corner frequency must correspond to the nominal frequency

 2-speed control unit:
 (see reference „ multi-stage-drive)
 
 400V   à   MSD 2
_____________________________________________________________________________________________________

 Scope of delivery:

  ·   Roof fan (DVW / DHW)
  ·   Documentation
_____________________________________________________________________________________________________

 Important notes:

 Air performance curves:

  The performance curves for these fan types have been measured on a inlet side chamber testing platform according to DIN  ISO  EN  5801 in mounting position A (free inlet; free outlet) and are valid for air with a density of 1.2 kg/m³ and indicate  the pressure increase Dpfa as a function of the air flow.

 Noise levels:
  The  bordered  values printed in the performance curve diagrams show the A weighted LWA8 sound power level (fan outlet).
  Determination of A-weighted LWA5 sound power level at fan inlet according to DIN 45 635, Part 38 is calculated as follows:

 LWA5 [dB(A)] = LWA6 [dB(A)] -3dB

  The "A" weighted sound pressure level LPA at a distance of 1 meter is calculated approximately by deducting 7 db(A) from the "A" weighted  sound  power  level. It  is  important to note that the reflection and room characteristic as well as natural frequencies  influence  the  sound  pressure  levels  a  different  way. The octave sound power level LWA at octave medium frequency you can find on the table on each fan type page.

 Erp-Information:
  Rosenberg fans have a specific (pressure-) ratio < 1,05 (pressure < 5000 Pa).

 Service life:
 For  maximum  service life of Rosenberg products please beware of the maintenance hints on the manual for each product type.

 Recycling and disposal:
 For recycling and disposal of Rosenberg products comply with applicable locally requirements and regulations.

Roof fans vertical outlet

From DVW 450-4 E to DVW 500-6-6 D
Base frame with bolts for tightening of inlet accessories and rectangular inlet cone made of galvanized steel. Rain hood and square casing made from seawater resistant aluminium. Motor supporting plate with integrated protection guard made from plastic coated round bar steel.

From DVW 560-4 D to DVW 800-8-8 K D

Base frame with bolts for tightening of inlet accessories and rectangular inlet cone made of galvanized steel and additionally plastic coated. Rain hood and square casing made from seawater resistant aluminium. Motor supporting plate with integrated protection guard made from plastic coated round bar steel up to size 710. Motor support made from welded and plastic coated rectangular tube as well as bird protection guards with size 800 and 900.


Fans are equipped with backward curved high efficiency impellers made of seawater resistant aluminium, mounted onto the rotor of a speed controllable external rotor motor. two levels according to quality level G 6.3 DIN/ISO 1940. Motor closed, protection I class IP 44/54 with protection against humidity and thermal contacts wired in windings from size 355.

Maintenance free ball bearings, closed on both sides, sealed for life. Easy access to the terminal box (not connected) in IP 54 under rain hood. Sizes 800 and 900 with backward curved high efficiency impeller, made from seawater resistant aluminium. Balanced on two levels according to quality level G 6.3 DIN/ISO 1940. Impeller in­stalled on motor shaft of an IEC standard motor, version B5. Motor in protection class IP 54, mounted under a removable hood component outside the air stream. Easy access to terminal box in protection class IP 55 after removal of the hood com­ponent.

Reference to Directives:
Declaration of incorporation and operating instruction are according to Machinery Directive 2006/42/EC, CE identification in accordance to EMC-Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and the Ecodesign-Directive 2009/125/EC.

 

For further information, please click the model below for detail.

DVW 450-4 E DVW 500-4 D DVW 560-4 D DVW 630-4 D DVW 710-6 D DVW 800-6 K D
DVW 450-4-4 D DVW 500-4 E DVW 560-4-4 D DVW 630-4-4 D DVW 710-6-6 D DVW 800-6-6 K D
DVW 450-6 D DVW 500-4-4 D DVW 560-6 D DVW 630-6 D DVW 710-8 D DVW 800-8 K D
DVW 450-6 E DVW 500-6 D DVW 560-6-6 D DVW 630-6-6 D DVW 710-8-8 D DVW 800-8-8 K D
DVW 450-6-6 D DVW 500-6 E DVW 560-8 D DVW 630-8 D    
DVW 450-8 E DVW 500-6-6 D DVW 560-8-8 D DVW 630-8-8 D    

Picture of roof fans DVW

Return to Top